• Title of article

    High heat flux facility GLADIS:: Operational characteristics and results of W7-X pre-series target tests

  • Author/Authors

    Greuner، نويسنده , , H. and Boeswirth، نويسنده , , B. and Boscary، نويسنده , , J. A. McNeely، نويسنده , , P.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    5
  • From page
    1444
  • To page
    1448
  • Abstract
    The new ion beam facility GLADIS started the operation at IPP Garching. The facility is equipped with two individual 1.1 MW power ion sources for testing actively cooled plasma facing components under high heat fluxes. Each ion source generates heat loads between 3 and 55 MW/m2 with a beam diameter of 70 mm at the target position. These parameters allow effective testing from probes to large components up to 2 m length. The high heat flux allows the target to be installed inclined to the beam and thus increases the heated surface length up to 200 mm for a heat flux of 15 MW/m2 in the standard operating regime. Thus the facility has the potential capability for testing of full scale ITER divertor targets. Heat load tests on the WENDELSTEIN 7-X pre-series divertor targets have been successfully started. These tests will validate the design and manufacturing for the production of 950 elements.
  • Journal title
    Journal of Nuclear Materials
  • Serial Year
    2007
  • Journal title
    Journal of Nuclear Materials
  • Record number

    1365809