Title of article :
Power operation with reduced heat transmitting tiles at tore supra
Author/Authors :
Mitteau، نويسنده , , R. M. Schlosser، نويسنده , , J. and Lipa، نويسنده , , M. and Durocher، نويسنده , , A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
3
From page :
844
To page :
846
Abstract :
Three lagging tiles – over 12054 – are present since 2006 on Tore Supra main limiter, an actively cooled high heat flux plasma-facing component. The deterioration is attributed to progressing cracking of the bond between the tiles and the copper based heat sink. It is observed by an infrared camera: the thermal time constant of the tiles during cool down increased by a factor of three during the experimental campaigns of 2006 where a high level of additional power was used repetitively during long pulses. An element with a defective tile is removed for inspection during the summer shut down of 2007. The bond is cracked on three quarters of the length. Although the defects are important, the defective tiles do not limit the operation.