• Title of article

    Power operation with reduced heat transmitting tiles at tore supra

  • Author/Authors

    Mitteau، نويسنده , , R. M. Schlosser، نويسنده , , J. and Lipa، نويسنده , , M. and Durocher، نويسنده , , A.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    3
  • From page
    844
  • To page
    846
  • Abstract
    Three lagging tiles – over 12054 – are present since 2006 on Tore Supra main limiter, an actively cooled high heat flux plasma-facing component. The deterioration is attributed to progressing cracking of the bond between the tiles and the copper based heat sink. It is observed by an infrared camera: the thermal time constant of the tiles during cool down increased by a factor of three during the experimental campaigns of 2006 where a high level of additional power was used repetitively during long pulses. An element with a defective tile is removed for inspection during the summer shut down of 2007. The bond is cracked on three quarters of the length. Although the defects are important, the defective tiles do not limit the operation.
  • Journal title
    Journal of Nuclear Materials
  • Serial Year
    2009
  • Journal title
    Journal of Nuclear Materials
  • Record number

    1366376