• Title of article

    Behaviour of helium after implantation in molybdenum

  • Author/Authors

    Viaud، نويسنده , , C. and Maillard، نويسنده , , S. and Carlot، نويسنده , , G. and Valot، نويسنده , , C. EGEA-GILABERT and M. E. CANDELA، نويسنده , , E. and Sauvage، نويسنده , , T. and Peaucelle، نويسنده , , C. and Moncoffre، نويسنده , , N.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    5
  • From page
    294
  • To page
    298
  • Abstract
    This study deals with the behaviour of helium in a molybdenum liner dedicated to the retention of fission products. More precisely this work contributes to evaluate the release of implanted helium when the gas has precipitated into nanometric bubbles close to the free surface. A simple model dedicated to calculate the helium release in such a condition is presented. The specificity of this model lays on the assumption that the gas is in equilibrium with a simple distribution of growing bubbles. This effort is encouraging since the calculated helium release fits an experimental dataset with a set of parameters in good agreement with the literature.
  • Journal title
    Journal of Nuclear Materials
  • Serial Year
    2009
  • Journal title
    Journal of Nuclear Materials
  • Record number

    1366792