Title of article
Double-supply-frequency pressure pulsation in annular linear induction pump, part II: reduction of pulsation by linear winding grading at both stator ends
Author/Authors
Araseki، Hideo نويسنده , , Preslitsky، Gennady V. نويسنده , , Ogorodnikov، Anatoly P. نويسنده , , Kirillov، Igor R. نويسنده ,
Issue Information
دوهفته نامه با شماره پیاپی سال 2000
Pages
-396
From page
397
To page
0
Abstract
In the previous work, the authors showed that the double-supply-frequency pressure pulsation comes from a disturbance of the electromagnetic force occurring near the stator ends, and hence the pressure pulsation may be reduced by some way that suppresses this disturbance, e.g. by a winding grading at the stator ends. In the present work, an experiment and a numerical analysis are carried out to verify the effect of linear winding grading. The experimental data and the numerical results show that this type of grading is an effective way to reduce the pressure pulsation. In addition, the experimental data reveals that the linear winding grading improves the pump efficiency.
Keywords
Core makeup tank , direct contact condensation , Heat transfer coefficients , High speed camera , Holographic inteferometer
Journal title
Nuclear Engineering and Design
Serial Year
2000
Journal title
Nuclear Engineering and Design
Record number
13841