• Title of article

    Validating CFD predictions of highly localized aerosol deposition in airway models: In vitro data and effects of surface properties

  • Author/Authors

    Holbrook، نويسنده , , Landon T. and Longest، نويسنده , , P. Worth، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2013
  • Pages
    16
  • From page
    6
  • To page
    21
  • Abstract
    Local deposition of pharmaceutical and environmental aerosols governs desorption, uptake, and biological response within the respiratory airways. Few studies have reported estimates of numerical microdosimetry and even fewer have compared these results with experiments. This study evaluated the effects of surface coating and roughness on the local deposition of inhaled coarse micrometer particles in an in vitro asymmetric double bifurcation geometry. The double bifurcation geometry is representative of airway generations 3–5 and includes mean asymmetry approximations from previous anatomical studies. Polystyrene latex 10 μm monodisperse particles were delivered at a steady state tracheal flow rate of 60 l/min (LPM) and mean local deposition patterns were resolved on a grid of 0.75 mm squares using fluorescent microscopy. The three airway geometry surfaces tested were unaltered, coated with silicone oil, and sanded-coated. For the hard plastic in vitro models employed, coating the surface was shown to be important in order to prevent bounce and re-entrainment of the particles. Sanding the models altered the local deposition profile in an uncontrolled way and is therefore not recommended for future experiments. The best overall match between the in vitro results and CFD simulations was the coated experimental geometry and coarse wall roughness simulations. For this case, the relative error between the experiments and simulations for total deposition was 6%. On a local deposition basis, cumulative lines of deposition fraction in the x and y-directions showed reasonable agreement between the experiments and simulations. However, some evidence of post-deposition particle rolling or spreading was observed with the coated experiments at the second bifurcation. Comparing experimental and CFD results cell by cell, higher maximum deposition enhancement factors (DEFs) were observed for the in vitro cases, perhaps due to factors not included in the CFD simulations. This result implies that previously predicted maximum DEF values from CFD simulations may be conservatively low and that actual values with in vitro models or in vivo may be even higher than predicted. In conclusion, this study provides a valuable new dataset for understanding the effects of surface characteristics on local deposition, assessing hotspot magnitude in the tracheobronchial airways, and validating CFD predictions.
  • Keywords
    Surface roughness , Surface coating , Modeling airway deposition , Airway particle deposition , microdosimetry , In vitro aerosol deposition
  • Journal title
    Journal of Aerosol Science
  • Serial Year
    2013
  • Journal title
    Journal of Aerosol Science
  • Record number

    1386260