Title of article :
Sensitivity of different prothrombin time assays to factor VII deficiency in canine plasma
Author/Authors :
Mischke، نويسنده , , R. and Diedrich، نويسنده , , M. and Nolte، نويسنده , , I.، نويسنده ,
Issue Information :
فصلنامه با شماره پیاپی سال 2003
Abstract :
The factor VII sensitivity of prothrombin time (PT) in dogs was tested using five different PT reagents and a commercial PT variant. The five PT reagents were used according to manufacturers’ instructions (standard test, PT[ST]) and also using a modified test instruction (modified test, PT[MT]). Plasma samples with defined factor VII levels (10–100%) were prepared by adding increasing quantities of canine factor VII deficient plasma to the pooled plasma of healthy dogs. Statistical comparison based on prothrombin time ratios (PTR = PT sample: PT measured for 100% factor VII activity level) revealed significant differences between different reagents for PT[ST] and also for PT[MT]. Factor VII activity at which PT was prolonged to the upper limit of the reference values (FVII[X0.975]) was 16–39% (PT[ST]) and 23–35% (PT[MT]). Factor VII sensitivity measured by PTR and also by FVII[X0.975] values, was higher in four of five PT reagents using PT[MT] when compared with PT[ST]. The results of this study indicate the importance of selecting a sensitive reagent and method for PT measurement and for careful interpretation of PT test results using canine plasma.
Keywords :
Prothrombin time , dog , Sensitivity , Factor VII deficiency
Journal title :
The Veterinary Journal
Journal title :
The Veterinary Journal