Title of article
Potential low frequency ground vibration (<6.3 Hz) impacts from underground LRT operations
Author/Authors
Wolf، نويسنده , , S، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
11
From page
651
To page
661
Abstract
Vibration sensitive research activities at the laboratories of the University of Washington (UW) Physics and Astronomy Building (PAB) were a critical issue for the design of the Sound Transit Link Light Rail LRT system in Seattle, Washington. A study was conducted to measure and predict low frequency ground vibration generated by the LRT operations. The Universityʹs concern was an on-going research experiment in gravity, which had sensitivity to vibration below 6.3 Hz. The experiment was located on an independent concrete slab in an area cut-out from the building foundation with no connection to the building structure. Another concern was the planned future construction of a Life Sciences Center with vibration sensitive test equipment. This paper presents the results of a study to estimate the ground displacement at these buildings using empirical measured data of a similar deep tunnel transit system and finite difference modelling analysis.