• Title of article

    35000 h of operational experience with the drum life assessment system in Trbovije

  • Author/Authors

    Gruden، Mihael نويسنده , , Voncina، Marko نويسنده , , Jan، Urban نويسنده , , Cucek، Mark نويسنده , , Pauser، Stane نويسنده ,

  • Issue Information
    دوهفته نامه با شماره پیاپی سال 1999
  • Pages
    -372
  • From page
    373
  • To page
    0
  • Abstract
    This paper deals with the operating experience of the power plant life assessment system observing the boiler drum only. The scope of the assessment system is the range of a thick wall vessel operating at temperatures below 400°C. The system was initiated by boiler drums with the same material properties having suffered ruptures during pressure test after urgent repairs on other steam generating equipment. The main concern was focused on the high life reduction during the ambient temperature 1.5 * p pressure test, when the actual damage cases occurred. With growing experience the evaluation of fatigue is extended to normal operation, start up and shut of periods. The systems have been enhanced and have successfully reduced the operational fatigue sources. The resulting improvement in material life use has been enhanced 4-5 times over the results from the first year in operation. © 1999 Elsevier Science S.A. All rights reserved.
  • Keywords
    Fracture toughness , Specimen reconstitution , Compact tension specimens , Charpy specimens
  • Journal title
    Nuclear Engineering and Design
  • Serial Year
    1999
  • Journal title
    Nuclear Engineering and Design
  • Record number

    14030