Title of article :
Experiments for entrainment rate of droplets in the annular regime
Author/Authors :
Lopez de Bertodano، نويسنده , , M.A. and Assad، نويسنده , , A. and Beus، نويسنده , , S.G.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
15
From page :
685
To page :
699
Abstract :
Two-fluid model predictions of film dryout in annular flow are limited by the uncertainties in the entrainment rate of droplets from the liquid film. The main cause of these uncertainties is the lack of separate effects experimental data in the range of the operating conditions in industrial applications. ter and Freon-113 entrainment rate data have been obtained in 10 mm tubes using the double film extraction technique. These experiments have been scaled to approach high-pressure steam–water flow conditions. The effects of surface tension and density ratio, missing from most previous data sets, have been systematically tested. trainment rate mechanism is scaled by the Kelvin–Helmholtz instability at the film surface. Based on this analysis and the new data, a new correlation is proposed that is valid for low-viscosity fluids in small ducts in the ripple-annular regime.
Keywords :
Atomization , Entrainment rate , Droplets , Liquid film , Two-fluid model , Film extraction , FREON , Annular flow