Title of article :
Interfacial shear in downward two-phase annular co-current flow
Author/Authors :
Hajiloo، نويسنده , , M. and Chang، نويسنده , , B.H. and Mills، نويسنده , , A.F.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Abstract :
Pressure drop has been determined experimentally for downward co-current annular two-phase flow, with water and air flow Reynolds numbers in the ranges 5100–27 200 and 3400–21 600, respectively. In order to investigate the effect of tube diameter, four tubes, of I.D.ʹs ranging from 1.56–4.12 cm, were tested. Special care was taken to eliminate effects of surfactants. The resulting skin friction coefficients were only in qualitative agreement with most previously reported data. At a fixed gas Reynolds number, a large increase in friction accompanied a decrease in tube diameter. Existing correlations were found to be unsuccessful for the present data.
Keywords :
Vertical downward flow , Pressure drop , Annular flow , Interfacial shear stress , Multi-phase flow
Journal title :
International Journal of Multiphase Flow
Journal title :
International Journal of Multiphase Flow