Title of article
Fatigue damage in cancellous bone: An experimental approach from continuum to micro scale
Author/Authors
Dendorfer، نويسنده , , S. E. Maier، نويسنده , , H.J. and Hammer، نويسنده , , J.، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2009
Pages
7
From page
113
To page
119
Abstract
Repeated loadings may cause fatigue fractures in bony structures. Even if these failure types are known, data for trabecular bone exposed to cyclic loading are still insufficient as the majority of fatigue analyses on bone concentrate on cortical structures. Despite its highly anisotropic and inhomogeneous structure, trabecular bone is treated with continuum approaches in fatigue analyses. The underlying deformation and damage mechanism within trabecular specimens are not yet sufficiently investigated.
present study different types of trabecular bone were loaded in monotonic and cyclic compression. In addition to the measurement of integral specimen deformations, optical deformation analysis was employed in order to obtain strain distributions at different scale levels, from the specimens’ surface to the trabeculae level. These measurements allowed for the possibility of linking the macroscopic and microscopic mechanical behaviour of cancellous bone. Deformations were found to be highly inhomogeneous across the specimen. Furthermore strains were found to already localise at very low load levels and after few load cycles. Microcracks in individual trabeculae were induced in the very early stage of cyclic testing. The results provide evidence of the capability of the method to supply essential data on the failure behaviour of individual trabeculae in future studies.
Keywords
Cancellous bone , Deformation behaviour , Damage , Mechanical behaviour , Measurement and testing , Fatigue
Journal title
Journal of the Mechanical Behavior of Biomedical Materials
Serial Year
2009
Journal title
Journal of the Mechanical Behavior of Biomedical Materials
Record number
1404321
Link To Document