Title of article
Quantitative measurement of solids distribution in gas–solid riser flows using electrical impedance tomography and gamma densitometry tomography
Author/Authors
Tortora، نويسنده , , P.R. and Ceccio، نويسنده , , S.L. and O’Hern، نويسنده , , T.J. and Trujillo، نويسنده , , S.M. and Torczynski، نويسنده , , J.R.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
24
From page
972
To page
995
Abstract
An electrical impedance tomography (EIT) system has been developed to non-invasively measure particle distributions in the riser of a pilot-scale circulating fluidized bed (CFB). Although EIT systems have often been applied to yield qualitative information about gas–solid flows, the present EIT system yields quantitative information that is validated by comparison to a gamma densitometry tomography (GDT) system. EIT and GDT were applied to the CFB riser (14-cm inner diameter, 5.77-m height) containing fluid catalytic cracking particles in air. The flows examined were annular with a dilute core and had average and near-wall solids volume fractions up to 0.25 and 0.66, respectively. For all cases, the average and near-wall solids volume fractions from EIT and GDT agreed to within 0.03 and 0.07, respectively. This good agreement suggests that, where feasible, EIT can be used in place of GDT, which is advantageous since EIT systems are often safer, less expensive, and faster than GDT systems.
Keywords
tomography , fluidized bed , EIT , GDT , Gas–solid , Riser
Journal title
International Journal of Multiphase Flow
Serial Year
2006
Journal title
International Journal of Multiphase Flow
Record number
1409872