Title of article :
Comment on “Correlation of entrainment for annular flow in horizontal pipes”, by Pan, L., Hanratty, T.J., Int. J. Multiphase flow, 28(3), (2002), pp. 385–408
Author/Authors :
Al-Sarkhi، نويسنده , , A. and Sarica، نويسنده , , C.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
2
From page :
535
To page :
536
Abstract :
The above referenced paper, published in International Journal of Multiphase Flow (Pan and Hanratty, 2002), proposed an entrainment fraction correlation for annular flow in horizontal pipes. The entrainment fraction in annular flow is defined as the ratio of the mass flow rate of the liquid droplets in the gas to the total mass flow of liquid, FE = WLE/WL. The proposed correlation was verified with experimental data for liquids with viscosities close to that of water. The proposed entrainment fraction correlation includes another correlation for the critical film flow rate, WF,cr to estimate a maximum entrainment fraction FE,max. It is shown that the critical film flow rate correlation can result in negative maximum entrainment fraction values, for low liquid flow rates.
Keywords :
Gas–liquid pipe flow , Annular flow , entrainment , Horizontal pipe