Title of article :
Enzyme modified membranes protected by plasma polymer layers
Author/Authors :
D. Janasek، نويسنده , , D. and Spohn، نويسنده , , U. and Kiesow، نويسنده , , A. and Heilmann، نويسنده , , A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Abstract :
A peroxidase modified membrane was stabilized by thin plasma polymer layer deposited using the monomers allylalcohol or hexamethyldisilazane. In comparison to the uncoated enzyme membrane, there is a significant operational stability improvement of the hydrogen peroxide detection. H2O2 can be detected in the range between 4 and 1000 μM. The sensor is stable for more than 1000 detections under flow injection conditions.
Keywords :
Chemiluminescence , Peroxidase , Hydrogen peroxide detection , Plasma polymer category:6 (biosensors)
Journal title :
Sensors and Actuators B: Chemical
Journal title :
Sensors and Actuators B: Chemical