• Title of article

    High-pressure gas–liquid equilibrium measurements by means of a double-chamber recirculation apparatus. Data on the system carbon dioxide–limonene at 50 and 70 °C

  • Author/Authors

    Gironi، نويسنده , , F. and Maschietti، نويسنده , , M.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    7
  • From page
    49
  • To page
    55
  • Abstract
    Measurements of the phase equilibria for the system carbon dioxide–limonene were performed at 50 and 70 °C in the pressure range 8.54–13.34 MPa. Both the liquid and the gas phase composition were measured. The experiments were carried out by means of a two-chamber recirculation apparatus. According to the procedure, in one of the chambers the gas–liquid equilibrium is established, whereas the second one contains only the gas phase which is continuously recirculated through the chambers to reduce time for equilibration. Before sampling, the chambers are separated to avoid disturbances of the equilibrium when reducing pressure during the withdrawal of the gas phase. Experimental data at 50 °C were used for the validation of the experimental method, through comparison with literature data, whereas those at 70 °C are mostly original. The experimental data were successfully correlated by means of a thermodynamic model based on the Peng–Robinson equation of state.
  • Keywords
    phase equilibrium , Double-chamber apparatus , Gas phase recirculation , limonene , Peng–Robinson equation of state , Supercritical carbon dioxide
  • Journal title
    Journal of Supercritical Fluids
  • Serial Year
    2010
  • Journal title
    Journal of Supercritical Fluids
  • Record number