Title of article
Identification of optimum inter-stage pressure for two-stage transcritical carbon dioxide refrigeration cycles
Author/Authors
Srinivasan، نويسنده , , K.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
5
From page
26
To page
30
Abstract
The disadvantage of high discharge temperatures associated with transcritical CO2 refrigeration cycles can be overcome by adopting two-stage compression with inter-cooling between the stages. This also helps in improving the overall volumetric efficiency and some power saving. This paper considers the criteria of minimum work of compression, equal discharge temperatures at the exit of each stage and minimum exergy loss during inter-stage and gas cooling for identifying inter-stage pressure. It is shown that the equality of stage discharge temperatures is a more useful criterion than the saving in power or improvement in COP because multi-staging has at best a marginal (<10%) effect on the latter. The criterion of minimal exergy loss in heat rejection also yields the same inter-stage pressures as the minimum work criterion. Optimum inter-stage pressure for each condition is identified for several evaporator and gas cooler outlet temperatures and expressed in terms of the inter-stage pressure index of the product of cycle operating pressure limits.
Keywords
Carbon dioxide , Supercritical compression , Refrigeration , Multi-stage system
Journal title
Journal of Supercritical Fluids
Serial Year
2011
Journal title
Journal of Supercritical Fluids
Record number
1423526
Link To Document