Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET
Author/Authors :
Kim، Hyeon Sik نويسنده Department of Nuclear Medicine, Chonnam National University Hwasun Hospital, Hwasun-Gun, Jeollanamdo, South Korea , , Cho، Sang Geon نويسنده Department of Nuclear Medicine, Chonnam National University Hospital, Hwasun-Gun, Jeollanamdo, South Korea , , Kim، Ju Han نويسنده Department of Cardiology, Chonnam National University Hospital, Hwasun-Gun, Jeollanamdo, South Korea , , Kwon، Seong Young نويسنده Department of Nuclear Medicine, Chonnam National University Hwasun Hospital, Hwasun, Jeollanam-do Kwon, Seong Young , Lee، Byeongil نويسنده Korea Photonics Technology Institute, Gwangju City, South Korea , , Bom، Hee Seung نويسنده Department of Nuclear Medicine, Chonnam National University Hwasun Hospital, Hwasun-Gun, Jeollanamdo, South Korea ,
Issue Information :
دوفصلنامه با شماره پیاپی 0 سال 2014
Pages :
7
From page :
104
To page :
110
Abstract :
Objective(s): In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; age: 57, 53, and 76 years) were reconstructed, using filtered back projection (FBP) and ordered subset expectation maximization (OSEM) methods. OSEM reconstruction consisted of OSEM_2I, OSEM_4I, and OSEM_6I with 2, 4, and 6 iterations, respectively. The images, reconstructed and filtered by Gaussian filters of 5, 10, and 15 mm, were obtained, as well as non-filtered images. Visual analysis of image quality (IQ) was performed using a 3-grade scoring system by 2 independent readers, blinded to the reconstruction and filtering methods of stress images. Then, signal-to-noise ratio (SNR) was calculated by noise and contrast recovery (CR). Stress and rest MBF and coronary flow reserve (CFR) were obtained for each method. IQ scores, stress and rest MBF, and CFR were compared between the methods, using Chi-square and Kruskal-Wallis tests. Results: In the visual analysis, IQ was significantly higher by 10 mm Gaussian filtering, compared to other sizes of filter (PP=0.923 and 0.855 for readers 1 and 2, respectively). SNR was significantly higher in 10 mm Gaussian filter. There was a significant difference in stress and rest MBF between several vascular territories. However CFR was not significantly different according to various filtering methods. Conclusion: Post-reconstruction Gaussian filtering with a filter size of 10 mm significantly enhances the IQ of N-13 ammonia PET-CT, without changing the results of CFR calculation.
Journal title :
Asia Oceania Journal of Nuclear Medicine and Biology
Serial Year :
2014
Journal title :
Asia Oceania Journal of Nuclear Medicine and Biology
Record number :
1423735
Link To Document :
بازگشت