• Title of article

    Prediction of soakout time using analytical models

  • Author/Authors

    Chakravarthy، نويسنده , , B and Cherukuri، نويسنده , , H.P and Wilhelm، نويسنده , , R.G، نويسنده ,

  • Issue Information
    فصلنامه با شماره پیاپی سال 2002
  • Pages
    9
  • From page
    15
  • To page
    23
  • Abstract
    In precision manufacturing enterprises, machine parts at nonstandard temperatures are often soaked to standard temperature prior to making any dimensional measurements. The soakout times are usually determined using lumped heat-transfer models where the part temperatures are assumed to be uniform. This article discusses conditions under which lumped model assumptions are valid by comparing lumped analyses for various shapes and materials with the more general finite element results. In addition, the effect of ambient temperature cycling on part response is also studied.
  • Keywords
    Metrology , Lumped models , finite element methods , Soakout time , Dimensional measurements , Thermal errors
  • Journal title
    Precision Engineering
  • Serial Year
    2002
  • Journal title
    Precision Engineering
  • Record number

    1428702