Title of article
Oscillation of a tilted circular pad on a droplet for the self-alignment process
Author/Authors
Kaneda، نويسنده , , Masayuki P. Yamamoto، نويسنده , , Michinori and Nakaso، نويسنده , , Koichi and Yamamoto، نويسنده , , Tsuyoshi and Fukai، نويسنده , , Jun، نويسنده ,
Issue Information
فصلنامه با شماره پیاپی سال 2007
Pages
8
From page
177
To page
184
Abstract
The seesaw-oscillation of a small circular pad on a single droplet was studied both numerically and experimentally. The circular pad with a diameter of 2.0–3.8 mm onto a water or glycerol droplet with a volume of 1–10 μL, and a bottom substrate with a smaller diameter than that of the pad were used in the experiment. The pad was then tilted and then the tilting fixture was quickly removed. The pad alternately oscillated and then finally stabilized in a horizontal position. The numerical model considering the surface tension and the viscous force of the droplet was developed and calculated using the same configurations as those in the experiment. The experimental and numerical data showed good agreement not only in terms of the oscillating frequency and damping ratio but the transient motion of the circular pad and instantaneous droplet surface shape.
Keywords
Droplet , Oscillation , Inclined pad , Surface tension force , Viscous force , Self-alignment