Title of article :
Wearable handwriting input device using magnetic field: 2nd report: Influence of misalignment of magnet and writing plane
Author/Authors :
Han، نويسنده , , Xinying and Seki، نويسنده , , Hiroaki and Kamiya، نويسنده , , Yoshitsugu and Hikizu، نويسنده , , Masatoshi، نويسنده ,
Issue Information :
فصلنامه با شماره پیاپی سال 2010
Pages :
6
From page :
425
To page :
430
Abstract :
In the past we proposed a wearable handwriting input device using magnetic field. This device requires mounting a permanent magnet onto the userʹs fingertip and operates by detecting the magnetic field generated by the magnet through two magnetic sensors attached at the wrist of the other hand. The position of the magnet is calculated by the vector of the magnetic field. The calculation assumes that the magnetic axis rests on a plane where the sensors lie, perpendicular to the vector formed by the two sensors. In this paper we study the level of error that may arise when this assumption is violated, by investigating four possible misalignments (two kinds of rotations of the magnet and two ways of positioning the writing plane) with comparing the result of experiment and simulation. We conclude that misalignment due to a z-axis rotation is non-negligible and is best avoided during usage.
Keywords :
Handwriting input , Wearable device , Magnetic field , Misalignment
Journal title :
Precision Engineering
Serial Year :
2010
Journal title :
Precision Engineering
Record number :
1429461
Link To Document :
بازگشت