Title of article :
Miniaturized structures for removal or selection of particles from liquid flow
Author/Authors :
Santos، نويسنده , , L.C. and Beraldo، نويسنده , , F.P. and Simُes، نويسنده , , E.W. and Carvalho، نويسنده , , A.T. and da Silva، نويسنده , , M.L.P.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Abstract :
The aim of this work was the development of miniaturized structures useful for retention and/or selection of particles and viscous substances from a liquid flow. The proposed low costs structures are similar to macroscopic wastewater treatment systems, named baffles, and allow disassemble. They were simulated using FEMLAB 3.2b package and manufactured in acrylic with conventional tools. Tests for retention or selection of particles in water or air and viscous fluids in water were carried out. Either in air or water particles with 50 μm diameter will be retained but not with 13 μm diameter. In aqueous flow, it is also possible the retention of viscous samples, such as silicone 350 cSt. The simulated results showed good agreement with experimental measurements. These miniaturized structures can be useful in sample pretreatment for chemical analysis and microorganism manipulation.
Keywords :
SIMULATION , Particle retention , Viscous material removal , Miniaturization , Square wave mixer
Journal title :
Sensors and Actuators B: Chemical
Journal title :
Sensors and Actuators B: Chemical