• Title of article

    HCl gas monitoring based on a QCM using morpholine-functional styrene-co-chloromethylstyrene copolymer coatings

  • Author/Authors

    Matsuguchi، نويسنده , , Masanobu and Kadowaki، نويسنده , , Yoshito and Noda، نويسنده , , Kazutoshi and Naganawa، نويسنده , , Ryuichi، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    5
  • From page
    462
  • To page
    466
  • Abstract
    Quartz resonators coated with various compositions of poly(styrene-co-chloromethyl styrene) reacted with morpholine as adsorption sites were fabricated for simply but accurately monitoring HCl gas in air. The exposure of all resonators to HCl gas irreversibly decreased the oscillation frequencies, indicating that these devices can be used for one-shot detection of HCl gas. The chemical structure and composition of the copolymer affected the sensitivity. The largest sensitivity was obtained for the copolymer having 40.0 mol% CMSt composition cross-linked with 5.0 mol% DVB. The sensitivity was 0.1 ppm/Hz for 10-min sensor operation, demonstrating a ppm level of HCl detection, although great interference was produced by changes in the humidity.
  • Keywords
    Cross-linked morpholine-functional copolymer , Gas sensor , QCM , HCl monitoring
  • Journal title
    Sensors and Actuators B: Chemical
  • Serial Year
    2007
  • Journal title
    Sensors and Actuators B: Chemical
  • Record number