Title of article :
Perchlorate-selective membrane sensors based on two nickel-hexaazamacrocycle complexes
Author/Authors :
Ganjali، نويسنده , , Mohammad Reza and Norouzi، نويسنده , , Parviz and Faridbod، نويسنده , , Farnoush and Yousefi، نويسنده , , Mohammad and Naji، نويسنده , , Leila and Salavati-Niasari، نويسنده , , Masoud، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
6
From page :
494
To page :
499
Abstract :
The perchlorate salts of nickel(II) complexes of 1,3,5,8,10,13-hexaazacyclotetradecane (1) and 1,8-tert-butyl-1,3,5,8,10,13-hexaazacyclotetradecane (2) were used in construction of PVC based membrane electrodes. These sensors show very good selectivity for ClO4− ions over a wide variety of anions. These electrodes exhibit Nernstian behavior with the slopes of 59.5 and 59.3 mV per decade for (1) and (2), respectively. The working concentration ranges of the sensors are 1.0 × 10−1–9.0 × 10−7 M (1) and 1.0 × 10−1–5.0 × 10−7 M (2) with the detection limits of 6.0 × 10−7 and 2.0 × 10−7 M, respectively. The response time of the both sensors is very fast, and can be used for 2 (I) and 12 (II) weeks in a pH range of 3.0–11.0. These electrodes were applied to the determination of perchlorate ions in wastewater and cattle urine samples.
Keywords :
Perchlorate , Azamacrocycle , PVC sensor
Journal title :
Sensors and Actuators B: Chemical
Serial Year :
2007
Journal title :
Sensors and Actuators B: Chemical
Record number :
1435570
Link To Document :
بازگشت