Title of article :
Fish freshness analysis using metallic potentiometric electrodes
Author/Authors :
Gil، نويسنده , , Luis and Barat، نويسنده , , José M. and Garcia-Breijo، نويسنده , , Eduardo and Ibaٌez، نويسنده , , Javier and Martيnez-Mلٌez، نويسنده , , Ramَn and Soto، نويسنده , , Juan M. Llobet، نويسنده , , Eduard and Brezmes، نويسنده , , Jesْs and Aristoy، نويسنده , , M.-Concepciَn and Toldrل، نويسنده , , Fidel، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
9
From page :
362
To page :
370
Abstract :
One of the fields where the idea of developing artificial electronic mammalian sense devices might be widely applied is in food analysis. In this field, one very complex attribute yet of great importance is that of freshness. For instance, freshness is one of the most significant parameters of fish quality in most markets. The state of fish freshness can be assessed by various indicators but most of them are costly, time-consuming and lack of aptness for in situ or on site monitoring. This makes that the development of simple and undemanding systems for the evaluation of fish freshness is still an unresolved goal. Based on this demand, we focused our attention on the use of unselective sensors for the potential development of low-cost and easy-to-use devices for the estimation of freshness. After a preliminary study with a number of different electrodes, simple Au and Ag wires were used for the analysis of the evolution of sea (Sparus aurata) bream fish stored throughout time. PCA and neuronal network analyses showed that it is possible to determine the post-mortem time elapsed in minced gilthead sea bream using simple potentiometric measurements, suggesting that this method could be used for the analysis and evaluation of fish freshness. In order to somehow validate the potentiometric protocol for freshness assessment, the method has been compared with the determination of fish freshness based on the analysis of the concentration of certain bio-molecules as a function of time after the death of the fish. Among different possibilities the K1 index that simultaneously measures the variation in the ATP metabolites inosine 5′-phosphate (IMP), inosine (Ino) and hypoxanthine (Hx) was used. A remarkable correlation has been found between the K1 index determined during 7 days and the potentials of the Au and Ag electrodes.
Keywords :
Electronic tongue , Metallic electrodes , FuzzyARTMAP , fish freshness
Journal title :
Sensors and Actuators B: Chemical
Serial Year :
2008
Journal title :
Sensors and Actuators B: Chemical
Record number :
1435893
Link To Document :
بازگشت