Title of article :
Electrochemical sensing of cadmium and lead ions at zeolite-modified electrodes: Optimization and field measurements
Author/Authors :
Senthilkumar، نويسنده , , S. and Saraswathi، نويسنده , , R.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
11
From page :
65
To page :
75
Abstract :
The scope for using a zeolite NH4-Y modified carbon paste electrode (ZYMCPE) in the voltammetric detection of Cd2+ and Pb2+ ions in ground water resources and industrial effluents is examined. The experimental conditions with respect to zeolite to graphite ratio in the electrode preparation, preconcentration time and electrolyte are optimized to maximize the sensitivity of the measurement. The detection limits are 1.0 μg L−1 for Cd2+ ion and 3.6 μg L−1 for Pb2+ ion. The excellent reproducibility of results obtained in the present study offers the possibility to develop commercial voltammetric sensors based on ZYMCPE for the two ions. The analytical results for two real samples (ground water and industrial effluent) agree very well with those obtained by atomic absorption spectroscopy.
Keywords :
Electrochemical sensor , Cadmium ion , Lead ion , Cyclic voltammetry , Zeolite-modified electrode , Preconcentration
Journal title :
Sensors and Actuators B: Chemical
Serial Year :
2009
Journal title :
Sensors and Actuators B: Chemical
Record number :
1437634
Link To Document :
بازگشت