Title of article :
Designing of MIP-based QCM sensor for the determination of Cu(II) ions in solution
Author/Authors :
Yang، نويسنده , , Zheng-peng and Zhang، نويسنده , , Chun-jing، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
6
From page :
210
To page :
215
Abstract :
A novel quartz crystal microbalance (QCM) sensor with a high selectivity and sensitivity has been developed for the determination of Cu(II) ions, based on the modification of Cu(II) ion-imprinted polymer (Cu(II)-IIP) film onto a quartz crystal. The performance of the developed MIP-QCM sensor was evaluated and the results indicated that a sensitive MIP-QCM sensor could be fabricated. The obtained MIP-QCM sensor presents high-selectivity monitoring of Cu(II) ions, better reproducibility, shorter response time (6 min), wider linear range (0.001–50 μM) and lower detection limit (8 × 10−4 μM). The practical analysis of the MIP-QCM sensor confirms the feasibility of Cu(II) determination in wastewater.
Keywords :
Cu(II) , QCM , Molecularly imprinted polymer (MIP) , Determination
Journal title :
Sensors and Actuators B: Chemical
Serial Year :
2009
Journal title :
Sensors and Actuators B: Chemical
Record number :
1437799
Link To Document :
بازگشت