Title of article :
Rapid and simple high-performance liquid chromatographic assay for the determination of metformin in human plasma and breast milk
Author/Authors :
Zhang، نويسنده , , Mei and Moore، نويسنده , , Grant A and Lever، نويسنده , , Michael G. Gardiner، نويسنده , , Sharon J and Kirkpatrick، نويسنده , , Carl M.J and Begg، نويسنده , , Evan J، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Pages :
5
From page :
175
To page :
179
Abstract :
A rapid and simple high-performance liquid chromatographic (HPLC) assay for the determination of metformin in human plasma and breast milk is described. After proteins were precipitated with acetonitrile, metformin and the internal standard buformin were resolved on a cation-exchange column and detected by UV detection at 236 nm. Standard curves were linear over the concentration range 20.0–4000 μg/l. Intra- and inter-day coefficients of variation were <9.0% and the limit of quantification was around 20 μg/l.
Keywords :
Metformin
Journal title :
Journal of Chromatography B
Serial Year :
2002