• Title of article

    Development and validation of a liquid chromatographic method for Casiopeina IIIi® in rat plasma

  • Author/Authors

    Fuentes-Noriega، نويسنده , , Inés and Ruiz-Ram??rez، نويسنده , , Lena and Tovar Tovar، نويسنده , , Araceli and Rico-Morales، نويسنده , , Héctor and Gracia-Mora، نويسنده , , Isabel، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    7
  • From page
    115
  • To page
    121
  • Abstract
    A sensitive and specific liquid chromatographic method using extraction with zinc sulfate has been developed for the determination of Casiopeina IIIi and validated over the linear range 5–100 μg/ml in 1 ml of rat plasma. The analysis was performed on a Symmetry C18 (5 μm) column. The mobile phase was methanol: 0.01 M phosphate buffer pH 6.5 (40:60, v/v). The column effluent was monitored at 262 nm. The results showed that the assay is sensitive at 5 μg/ml. Maximum intra-day coefficient of variation was 10.6%. The recovery obtained in plasma was 87.2%. The method was used to perform protein binding studies by equilibrium dialysis in rat plasma and was found to be satisfactory.
  • Keywords
    Casiopeina IIIi
  • Journal title
    Journal of Chromatography B
  • Serial Year
    2002
  • Journal title
    Journal of Chromatography B
  • Record number

    1453592