Title of article
High-performance liquid chromatographic method for the determination of gabapentin in human plasma
Author/Authors
Zhu، نويسنده , , Z and Neirinck، نويسنده , , L، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
6
From page
307
To page
312
Abstract
A sensitive high-performance liquid chromatography (HPLC) method using UV detection for the determination of gabapentin in human plasma has been developed. In this method, gabapentin was extracted from human plasma with a reversed-phase solid-phase extraction (SPE) cartridge followed by derivatization with phenylisothiocyanate. Analysis was achieved by using a HPLC system that was equipped with a UV detector. The quantitation limit of gabapentin in human plasma was 0.03 μg/ml. The method is sensitive with excellent selectivity and reproducibility and it has been applied to a bioequivalence clinical study with great success.
Keywords
Gabapentin
Journal title
Journal of Chromatography B
Serial Year
2002
Journal title
Journal of Chromatography B
Record number
1454204
Link To Document