Title of article :
Determination of tezosentan, a parenteral endothelin receptor antagonist, in human plasma by liquid chromatography–tandem mass spectrometry
Author/Authors :
van Giersbergen، نويسنده , , Paul L.M. and Wipfli، نويسنده , , Peter and Dingemanse، نويسنده , , Jasper، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
5
From page :
369
To page :
373
Abstract :
An analytical method was developed for the quantification of tezosentan in human plasma obtained in clinical studies. The method was linear in the range 1 to 512 ng/ml. After liquid–liquid extraction, the samples were analyzed by reversed-phase HPLC with tandem mass spectrometry. The limit of quantification was 1 ng/ml and the extraction recovery was at least 88.2%. Intra- and inter-assay coefficients of variation were below 10%. Stability tests revealed that tezosentan is stable under the different conditions tested.
Keywords :
Tezosentan
Journal title :
Journal of Chromatography B
Serial Year :
2003
Journal title :
Journal of Chromatography B
Record number :
1455627
Link To Document :
بازگشت