Title of article :
Two different clean-up procedures for liquid chromatographic determination of ochratoxin A in urine
Author/Authors :
Domijan، نويسنده , , Ana-Marija and Peraica، نويسنده , , Maja and Mileti?-Medved، نويسنده , , Marica and Luci?، نويسنده , , Ana and Fuchs، نويسنده , , Radovan، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
5
From page :
317
To page :
321
Abstract :
This paper describes two different procedures for extraction of ochratoxin A (OTA) from urine samples: one using acidic chloroform–methanol mixture, followed by solid-phase extraction (SPE) clean-up and the other using commercial Chem Elut columns and a chloroform–formic acid mixture. The recovery of OTA using the procedure with silica gel columns was 82% with a R.S.D.<8.4% and the detection and quantitation limits were 0.5 and 1.5 ng OTA/ml, respectively. The recovery of OTA in the second procedure with urine samples purified only on commercial Chem Elut columns was 95% with R.S.D.<4.0%, and detection and quantitation limits 0.3 and 0.9 ng/ml, respectively. Both procedures of OTA extraction effectively eliminate interfering substances and give reliable and repeatable results. However, the procedure with Chem Elut columns gave higher recovery and lower detection and quantitation limits. It was successfully applied in determining OTA in human urine samples.
Keywords :
Clean-up procedures , Ochratoxin A
Journal title :
Journal of Chromatography B
Serial Year :
2003
Journal title :
Journal of Chromatography B
Record number :
1456225
Link To Document :
بازگشت