Title of article :
Liquid chromatographic assay for dicloxacillin in plasma
Author/Authors :
Alderete، نويسنده , , Oscar and Gonzلlez-Esquivel، نويسنده , , Dinora F and Misael Del Rivero، نويسنده , , L and Castro Torres، نويسنده , , Nelly، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
4
From page :
353
To page :
356
Abstract :
A simple high-performance liquid chromatographic method for the determination of dicloxacillin in plasma has been developed. The method only requires 0.5 ml of plasma, phosphate buffer solution (pH=4.7), acidification with 0.5N hydrochloride acid and liquid extraction with dichloromethane. Posterior evaporation of organic under nitrogen steam and redissolution in mobile phase is carried out. The analysis was performed on a Spherisorb C18 (5 μm) column, using methanol–0.05 M phosphate buffer, pH=4.7 (75:25; v/v) as mobile phase, with ultraviolet detection at 220 nm. Results showed that the assay is sensitive: 0.5 μg/ml. The response is linear in the range of 0.5–10 μg/ml. Maximum inter-day coefficient of variation was 12.4%. Mean extraction recovery obtained was 96.95%. Stability studies showed that the loss was not higher than 10%, samples are stable at room temperature for 6 h, at −20 °C for 2 months, processed samples were stable at least for 24 h and also after two freeze–thaw cycles. The method has been used to perform pharmacokinetic and bioequivalence studies in humans.
Keywords :
Dicloxacillin
Journal title :
Journal of Chromatography B
Serial Year :
2004
Journal title :
Journal of Chromatography B
Record number :
1456759
Link To Document :
بازگشت