Title of article :
High-performance liquid chromatography measurement of hyperforin and its reduced derivatives in rodent plasma
Author/Authors :
Rozio، نويسنده , , M. and Fracasso، نويسنده , , C. and Riva، نويسنده , , A. and Morazzoni، نويسنده , , P. and Caccia، نويسنده , , S.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Abstract :
A reverse-phase high-performance liquid chromatography method was developed for the determination of hyperforin and its reduced derivatives octahydrohyperforin and tetrahydrohyperforin in rodent plasma. The procedure includes solid-phase extraction from plasma using the Baker 3cc C8 cartridge, resolution on the Symmetry Shield RP8 column (150 mm × 4.6 mm, i.d. 3.5 μm) and UV absorbance detection at 300 nm. The assay was linear over a wide range, with an overall coefficient of variation less than 10% for all compounds. The precision and accuracy were within acceptable limits and the limit of quantitation was sufficient for studies preliminarily assessing the disposition of tetrahydrohyperforin and octahydrohyperforin in the mouse and rat.
Keywords :
hyperforin , Tetrahydrohyperforin , Octahydrohyperforin , Pharmacokinetic , Rodents
Journal title :
Journal of Chromatography B
Journal title :
Journal of Chromatography B