• Title of article

    Validation study of a method for assaying DE-310, a macromolecular carrier conjugate containing an anti-tumor camptothecin derivative, and the free drug in human plasma by HPLC and LC/MS/MS

  • Author/Authors

    Oguma، نويسنده , , Toshihiro and Cicci، نويسنده , , Dino and Gaudette، نويسنده , , Fleur and Gauthier-Dubois، نويسنده , , Ginette and Guilbaud، نويسنده , , Rudolf and Atsumi، نويسنده , , Ryo، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    8
  • From page
    249
  • To page
    256
  • Abstract
    DE-310 is a macromolecular carrier conjugate containing an anti-tumor camptothecin derivative, DX-8951, conjugated to a water-soluble polymer by means of a peptide spacer. New assay methods have been developed to determine the polymer-bonded DX-8951 conjugate, free DX-8951, and Glycyl-DX-8951 in human plasma. Solid-phase extraction was used to extract free DX-8951 and Glycyl-DX-8951 from plasma, and LC/MS/MS (Method I) was used to determine the amount of each analyte. Protein precipitation was used to extract Conjugated DX-8951, which was then digested with thermolysin. HPLC (Method II) was used to determine the productive compound (Phenylalanyl-Glycyl-DX-8951). The lower limit of quantitation of DX-8951 was 50 pg/ml, of Glycyl-DX-8951 was 80 pg/ml, and of Conjugated DX-8951 was 100 ng/ml (as DX-8951 equivalent). Both methods showed satisfactory sensitivity, precision, and accuracy.
  • Keywords
    HPLC , LC/MS/MS , DE-310 , camptothecin
  • Journal title
    Journal of Chromatography B
  • Serial Year
    2005
  • Journal title
    Journal of Chromatography B
  • Record number