Title of article :
Liquid chromatography–electrospray mass spectrometry determination of carbamazepine, oxcarbazepine and eight of their metabolites in human plasma
Author/Authors :
Breton، نويسنده , , Hélène and Cociglio، نويسنده , , Marylène and Bressolle، نويسنده , , Françoise and Peyriere، نويسنده , , Hélène and Blayac، نويسنده , , Jean Pierre and Hillaire-Buys، نويسنده , , Dominique، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
11
From page :
80
To page :
90
Abstract :
Carbamazepine (CBZ) and oxcarbazepine (OXCBZ) are both antiepileptic drugs, which are prescribed as first-line drugs for the treatment of partial and generalized tonic–clonic epileptic seizures. In this paper, a specific and sensitive liquid chromatography–electrospray ionization mass spectrometry method was described for the simultaneous determination of carbamazepine (CBZ), oxcarbazepine (OXCBZ) and eight of their metabolites [CBZ-10,11-epoxide (CBZ-EP), 10,11-dihydro-10,11-trans-dihydroxy-carbamazepine (DiOH-CBZ), 10-hydroxy-10,11-dihydroCBZ (10-OH-CBZ), 2-hydroxycarbamazepine (2-OH-CBZ), 3-hydroxycarbamazepine (3-OH-CBZ), iminostilbene (IM), acridone (AO) and acridine (AI)] in human plasma. The work-up procedure involved a simple precipitation with acetone. Separation of the analytes was achieved within 50 min using a Zorbax eclipse XD8 C8 analytical column. The mobile phase consisted of a mixture of acetonitrile–formate buffer (2 mM, pH 3). Detection was performed using a quadrupole mass spectrometer fitted with an electrospray ion source. Mass spectrometric data were acquired in single ion recording mode at m/z 237 for CBZ, m/z 180 for CBZ-EP and AI, m/z 236 for OXCBZ, m/z 237 for 10-OH-CBZ, m/z 253 for 2-OH-CBZ, 3-OH-CBZ and DiOH-CBZ, m/z 196 for AO and m/z 194 for IM. For all analytes, the drug/internal standard peak height ratios were linked via a quadratic relationship to plasma concentrations. The extraction recovery averaged 90% for CBZ, 80% for OXCBZ and was 80–105% for the metabolites. The lower limit of quantitation was 0.5 mg/l for CBZ, 0.4 mg/l for OXCBZ and ranged from 0.02 to 0.3 mg/l for the metabolites. Precision ranged from 2 to 13% and accuracy was between 86 and 112%. This method was found suitable for the analysis of plasma samples collected during therapeutic drug monitoring of patients treated with CBZ or OXCBZ.
Keywords :
Liquid chromatography–mass spectrometry , carbamazepine , Oxcarbazepine , Validation , metabolites
Journal title :
Journal of Chromatography B
Serial Year :
2005
Journal title :
Journal of Chromatography B
Record number :
1462462
Link To Document :
بازگشت