Title of article
LC/MS/MS measurement of penicillin G in bovine plasma, urine, and biopsy samples taken from kidneys of standing animals
Author/Authors
Heller، نويسنده , , David N. and Smith، نويسنده , , Michelle L. and Chiesa، نويسنده , , O. Alberto and Moulton، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
9
From page
91
To page
99
Abstract
Methods for the measurement of penicillin concentration in bovine plasma, kidney and urine were developed and validated. Detection was based on liquid chromatography/tandem mass spectrometry (LC/MS/MS). Phenethecillin was used as an internal standard. Plasma was extracted with acetonitrile using a method with a calculated limit of quantitation (LOQ) of 12 ng/mL. Kidney samples were homogenized in water and acetonitrile, then cleaned up on C18-bonded silica SPE cartridges. The LOQ of this procedure was 10 ng/g. Urine samples were diluted, filtered, and analyzed directly. The LOQ of this procedure was 63 ng/mL. The overall accuracy for plasma was 103% with coefficient of variation (CV) of 3%; for kidney, 96% and 11%, respectively, and for urine, 98% and 4%, respectively. These methods were applied to the analysis of plasma, urine, and kidney biopsy samples taken from standing animals that had been dosed with penicillin.
Keywords
penicillin , RESIDUE ANALYSIS , PLASMA , urine , Kidney , Quantification , Liquid chromatography–tandem mass spectrometry
Journal title
Journal of Chromatography B
Serial Year
2006
Journal title
Journal of Chromatography B
Record number
1462557
Link To Document