Title of article :
Development and validation of a sensitive assay of valproic acid in human plasma by high-performance liquid chromatography without prior derivatization
Author/Authors :
Amini، نويسنده , , Hossein and Javan، نويسنده , , Mohammad and Ahmadiani، نويسنده , , Abolhassan، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
Sensitive and selective determination of valproic acid in plasma by high-performance liquid chromatography (HPLC) is usually achieved with pre-column derivatization. In the present work, the derivatization is omitted due to using a simple but highly selective plasma extraction procedure and an optimized chromatographic condition. Valproic acid and the internal standard octanoic acid were extracted from plasma samples with n-hexane under acidic condition followed by back-extraction into diluted triethylamine. Chromatography was performed on a CN column (250 × 4.6 mm, 5 μm) under isocratic elution with acetonitrile–40 mM aqueous sodium dihydrogen phosphate (30:70, v/v), pH 3.5. Detection was made at 210 nm and analyses were run at a flow-rate of 1 ml/min. The method was specific and sensitive with a quantification limit of 1.25 μg/ml and a detection limit of 0.1 μg/ml in plasma. The mean absolute recovery for valproic acid using the present plasma extraction procedure was 75.8%. The intra- and inter-day coefficient of variation and percent error values of the assay method were all in acceptable range. Calibration curves were linear (r > 0.999) from 1.25 to 320 μg/ml in plasma.
Journal title :
Journal of Chromatography B
Journal title :
Journal of Chromatography B