Title of article :
Determination of lapatinib (GW572016) in human plasma by liquid chromatography electrospray tandem mass spectrometry (LC–ESI-MS/MS)
Author/Authors :
Bai، نويسنده , , Feng and Freeman III، نويسنده , , Burgess B. and Fraga، نويسنده , , Charles H. and Fouladi، نويسنده , , Maryam and Stewart، نويسنده , , Clinton F.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
A sensitive method for the determination of lapatinib (GW572016) in human plasma was developed using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Plasma samples (100 μL) were prepared using solid phase extraction (SPE) columns, and 6.0 μL of the reconstituted eluate was injected onto a Phenomenex® CuroSil-PFP 3 μ analytical column (50 mm × 2.0 mm) with an isocratic mobile phase. Analytes were detected with a PE SCIEX API-365 LC–MS/MS system at unit (Q1) and low (Q3) resolution in positive multiple reaction monitoring mode (m/z 581 (precursor ion) to m/z 364 (product ion) for lapatinib). The mean recovery for lapatinib was 75% with a lower limit of quantification of 15 ng/mL (S/N = 11.3, CV ≤ 14%). This method was validated over a linear range of 100–10,000 ng/mL, and results from a 5-day validation study demonstrated good within-day and between-day precision and accuracy. This method has been used to measure plasma lapatinib concentrations in a Phase I study in children with cancer.
Keywords :
Laptinib (GW572016) , Electrospray tandem mass spectrometry (LC–ESI-MS/MS) , Liquid chromatography , PLASMA
Journal title :
Journal of Chromatography B
Journal title :
Journal of Chromatography B