Abstract
Reversed-phase-high-performance liquid chromatographic method with electrochemical detection has proven to be a highly sensitive and selective method for determination of trace components in complex biological samples, and the electrochemical detector becomes an important alternative tool to ultraviolet and fluorescence detectors. A rapid and sensitive method for the accurate determination of metoclopramide, hydrochlorothiazide, imipramine and diclofenac in serum or plasma samples is described. The method is based on liquid–liquid extraction. The compounds were separated on C-18 column as stationary phase with a different binary mixture as mobile phase. Proposed method was validated with respect to specificity, linearity range, limit of detection and quantitation, precision, accuracy and successfully applied in a pharmacokinetic studies.
Keywords
RP-HPLC/ECD , metoclopramide , Hydrochlorothiazide , Imipramine , Diclofenac , Pharmacokinetics