• Title of article

    Determination of echinacoside in rat serum by reversed-phase high-performance liquid chromatography with ultraviolet detection and its application to pharmacokinetics and bioavailability

  • Author/Authors

    Jia، نويسنده , , Cunqin and Shi، نويسنده , , Haiming and Wu، نويسنده , , Xiangmei and Li، نويسنده , , Yinzeng and Chen، نويسنده , , Jingjing and Tu، نويسنده , , Pengfei، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    6
  • From page
    308
  • To page
    313
  • Abstract
    A rapid and simple high-performance liquid chromatographic (HPLC) method has been developed and validated for the determination of echinacoside (ECH) in rat serum. After protein precipitation of serum sample with trichloroacetic acid, the supernatant was directly injected and analyzed on a C18 CapcellACR analytical column (150 mm × 4.6 mm I.D. 5 μm) with a mobile phase consisting of acetonitrile–0.5% acetic acid (15.5:84.5, v/v). The UV detector was set at 330 nm. The lower limit of detection and quantification were 9 and 29.2 ng/mL, respectively, and the calibration curves were linear over the concentration range of 29.2–18250 ng/mL. The assay method was successfully applied to the study of the pharmacokinetics and bioavailability of ECH in rat.
  • Keywords
    Bioavailability , HPLC , Echinacoside , Phenylethanoid glycoside , Pharmacokinetics
  • Journal title
    Journal of Chromatography B
  • Serial Year
    2006
  • Journal title
    Journal of Chromatography B
  • Record number

    1463669