• Title of article

    On the adequacy of distribution curves used in coal cleaning – A statistical analysis

  • Author/Authors

    Mohanta، نويسنده , , S. and Mishra، نويسنده , , B.K.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    7
  • From page
    2262
  • To page
    2268
  • Abstract
    The performance of a gravity separator treating coal is commonly determined by plotting a Tromp curve which is basically a plot of partition coefficients against average specific gravity. There are many mathematical models proposed in the literature to represent this curve but selecting the most appropriate model for a given application is not straightforward. As the model is always tentative, it is necessary to examine the adequacy of the model for a particular process. To ascertain the adequacy and the reliability of a model, we consider six different mathematical models available in the literature and determine their suitability for representing the water-only cyclone data. The best model is selected in three steps by adopting a statistical analysis approach.
  • Keywords
    Coal cleaning , Distribution curve , F-distribution , Outliers , t statistic
  • Journal title
    Fuel
  • Serial Year
    2009
  • Journal title
    Fuel
  • Record number