Title of article :
Sensitive simultaneous determination of ciclesonide, ciclesonide-M1-metabolite and fluticasone propionate in human serum by HPLC–MS/MS with APPI
Author/Authors :
Mascher، نويسنده , , Hermann J. and Zech، نويسنده , , Karl and Mascher، نويسنده , , Daniel G.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
9
From page :
84
To page :
92
Abstract :
A new and very sensitive analytical method has been developed and validated to jointly determine the anti-inflammatory drug ciclesonide (CIC), its active principle metabolite M1 (CIC-M1) and fluticasone propionate (FP) in human serum, in the low concentration range from 10 to 1000 pg/mL. This was accomplished by high-performance liquid chromatography and tandem mass spectrometry using atmospheric pressure photo ionisation (HPLC–MS/MS with APPI) using 0.5 mL of serum. Serum was mixed with the internal standards (IS) D11-CIC and D11-CIC-M1 and extracted with diisopropylether. A gradient with acetonitrile (containing 10 mM of acetic acid and 10% of acetone) was used. HPLC–MS/MS of the acetic acid adducts of the analytes was performed in negative mode. The novel aspect of this method is that instead of the dopant being introduced directly into the source by means of an external HPLC pump, it was added to the mobile phase. This provided significantly better sensitivity than the usual method of in-source addition of the dopant, and with no loss in HPLC performance. Sensitivity for the analytes was about four times greater than with either APCI or ESI. Validation was performed in three batches. The inter-batch precision (CV) of the quality control samples in human serum ranged from 4.08% to 6.78% for CIC, from 2.57% to 7.74% for CIC-M1, and from 2.38% to 9.61% for FP. The inter-batch accuracy (with reference to the mean value) of the quality control samples in human serum ranged from 99.3% to 110.0% for CIC, from 101.8% to 104.7% for CIC-M1, and from 100.4% to 101.8% for FP. Calibration data and LLOQ data are also presented in this paper. The analytes were stable in human serum over three freeze/thaw cycles, or for 4 h at room temperature, or for at least 18 months when stored at below −20 °C. This method was used for quantifying the analytes after inhalation of low-μg amounts of the drugs by patients.
Keywords :
Atmospheric pressure photo ionisation , Tandem mass spectrometry , Liquid chromatography , Ciclesonide , Fluticasone propionate , Human serum
Journal title :
Journal of Chromatography B
Serial Year :
2008
Journal title :
Journal of Chromatography B
Record number :
1466029
Link To Document :
بازگشت