Title of article :
Sensitive chiral high-performance liquid chromatographic determination of anthelmintic flubendazole and its phase I metabolites in blood plasma using UV photodiode-array and fluorescence detection: Application to pharmacokinetic studies in sheep
Author/Authors :
Nobilis، نويسنده , , Milan and Vyb?ralov?، نويسنده , , Zuzana and K???ov?، نويسنده , , Veronika and Kub??ek، نويسنده , , Vladim?r and Soukupov?، نويسنده , , Marie and Lamka، نويسنده , , Ji?? and Szot?kov?، نويسنده , , Barbora and Sk?lov?، نويسنده , , Lenka، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Abstract :
Although benzimidazole anthelmintic flubendazole, methyl ester of [5-(4-fluorobenzoyl)-1H-benzimidazol-2-yl]carbamic acid, is extensively used in veterinary and human medicine for the treatment of gastrointestinal parasitic helmint infections, reliable data about its pharmacokinetics in various species have not been reported. Our previous work [M. Nobilis, Th. Jira, M. Lísa, M. Holčapek, B. Szotáková, J. Lamka, L.Skálová, J. Chromatogr. A 1149 (2007) 112–120] had described the stereospecificity of carbonyl reduction during phase I metabolic experiments in vitro. For in vivo pharmacokinetic studies, further improvement and optimization of bioanalytical HPLC method in terms of sensitivity and selectivity was necessary. Hence, a modified chiral bioanalytical HPLC method involving both UV photodiode-array and fluorescence detection for the determination of flubendazole, both enantiomers of reduced flubendazole and hydrolyzed flubendazole in the extracts from plasma samples was tested and validated. Albendazole was used as an internal standard. Sample preparation process involved a pH-dependent extraction of the analytes from the blood plasma into tert-butylmethyl ether. Chromatographic separations were performed on a Chiralcel OD-R 250 mm × 4.6 mm column with mobile phase methanol-1 M NaClO4 (75:25, v/v) at the flow rate 0.5 ml min−1. In quantitation, selective UV absorption maxima of 290 nm (for reduced flubendazole), 295 nm (for albendazole), 310 nm (for flubendazole) and 330 nm (for hydrolyzed flubendazole) were used in the UV photodiode-array detection, and λ(exc.)/λ(emis.) = 228 nm/310 nm (for reduced flubendazole) and λ(exc.)/λ(emis.) = 236 nm/346 nm (for albendazole) were set on the fluorescence detector. The fluorescence detection was approximately 10-times more sensitive than the UV detection. Each HPLC run lasted 27 min. The validated chiral HPLC-PDA-FL method was employed in the pharmacokinetic studies of flubendazole in sheep. The stereospecificity of the enzymatic carbonyl reduction of flubendazole was also observed in vivo. (+)-Reduced flubendazole was found to be the principal metabolite in ovine blood plasma and only low concentrations of hydrolyzed flubendazole, the parent flubendazole and (−)-reduced flubendazole were detected in this biomatrix.
Keywords :
Benzimidazole anthelmintics , Phase I flubendazole metabolites , Pharmacokinetics in sheep , Chiral HPLC with UV photodiode-array and fluorescence detection , Stereospecificity of the carbonyl reduction of flubendazole
Journal title :
Journal of Chromatography B
Journal title :
Journal of Chromatography B