Title of article :
Urinary amino acid analysis: A comparison of iTRAQ®–LC–MS/MS, GC–MS, and amino acid analyzer
Author/Authors :
Kaspar، نويسنده , , Hannelore and Dettmer، نويسنده , , Katja and Chan، نويسنده , , Queenie and Daniels، نويسنده , , Scott and Nimkar، نويسنده , , Subodh and Daviglus، نويسنده , , Martha L. and Stamler، نويسنده , , Jeremiah and Elliott، نويسنده , , Paul and Oefner، نويسنده , , Peter J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Abstract :
Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC–MS) and liquid chromatography–tandem mass spectrometry (LC–MS/MS) of propyl chloroformate and iTRAQ® derivatized amino acids, respectively, to conventional amino acid analysis. The GC–MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC–MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ® tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC–MS, and iTRAQ®–LC–MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27 ± 5.22, 21.18 ± 10.94, and 18.34 ± 14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39 ± 5.35, 6.23 ± 3.84, and 35.37 ± 29.42. Both GC–MS and iTRAQ®–LC–MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines.
Keywords :
amino acids , urine , Liquid chromatography–tandem mass spectrometry , Amino acid analyzer , Stable isotope dilution , iTRAQ , Propyl chloroformate , Gas chromatography–mass spectrometry , Precolumn derivatization
Journal title :
Journal of Chromatography B
Journal title :
Journal of Chromatography B