Title of article :
Implementation of a cost-effective HPLC/UV-approach for medical routine quantification of donepezil in human serum
Author/Authors :
Koeber، نويسنده , , Ralf and Kluenemann، نويسنده , , Hans-Hermann and Waimer، نويسنده , , Reinhold and Koestlbacher، نويسنده , , Anton and Wittmann، نويسنده , , Markus and Brandl، نويسنده , , Regina and Doerfelt، نويسنده , , Anett and Jahner، نويسنده , , Tatjana and Melchner، نويسنده , , Doris and Haen، نويسنده , , Ekkehard، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Abstract :
A novel, simple, specific and sensitive high performance liquid chromatography (HPLC) assay for the detection and quantification of donepezil in serum of demented patients has been developed and validated. The analytical procedure involves an offline serum preextraction using solid phase extraction (SPE) cartridges (Oasis® HLB, Waters Co). The chromatographic analyses were performed on a Dionex HPLC system with a Phenomenex Luna Phenyl-Hexyl analytical column, and a mobile phase with the two components 0.02 mol/l phosphate buffer and acetonitrile. The flow rate was 0.4 ml/min. For the detection of donepezil three different UV wavelengths were used as an interference-control check. Interference tests between donepezil and 100 of the most commonly used concomitant medications allow quantification of donepezil under the polypharmaceutical conditions of the daily clinical routine. The retention time for donepezil was 12.1 min. The method was validated according to the guidelines of the Society of Toxicology and Forensic Chemistry (GTFCh): The calibration curve was linear over a concentration range from 5 to 160 ng/ml (n = 8/r2 > 0.999). No endogenous compounds were found to interfere with the analyte, which was shown by retention times for the comedication most often prescribed to demented patients. The method had an accuracy of >85%. Intra- and inter-assay coefficients of variation were <6% and <8%, respectively, at three different concentrations. The limit of quantification (LOQ) and the limit of detection (LOD) were found to be 6.1 and 1.7 ng/ml for donepezil. Application of the method to patient serum samples discovered that concentrations suggested as “therapeutic” in the literature may only be reached either by high, off-label dosages or by utilization of inhibitory metabolic effects of the comedication.
Keywords :
analytical methods , Dose-related reference range , Therapeutic drug monitoring (TDM) , Individualized dosage , Antidementia drugs , donepezil
Journal title :
Journal of Chromatography B
Journal title :
Journal of Chromatography B