Title of article :
Direct water removing from frozen brown coal at −20 °C
Author/Authors :
Kanda، نويسنده , , Hideki and Li، نويسنده , , Peng and Makino، نويسنده , , Hisao، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Abstract :
The liquefied dimethyl ether (DME) was used to dewater the frozen brown coal under a designed experimental condition at −20 °C. With this method, 98.1 wt.% of the initial water was removed from the frozen brown coal. The properties of the brown coal were not changed obviously after the dewatering treatment. By means of differential scanning calorimetry measurement, it is found that the water in tested brown coal existed in both ice and non-freezing forms at the temperature below frozen point indicating that both forms of water can be directly removed by DME at frigid condition.
Keywords :
Dewatering , Brown coal , Non-freezing water , Dimethyl ether