• Title of article

    GC–MS determination of creatinine in human biological fluids as pentafluorobenzyl derivative in clinical studies and biomonitoring: Inter-laboratory comparison in urine with Jaffé, HPLC and enzymatic assays

  • Author/Authors

    Tsikas، نويسنده , , Dimitrios and Wolf، نويسنده , , Alexander and Mitschke، نويسنده , , Anja and Gutzki، نويسنده , , Frank-Mathias and Will، نويسنده , , Wolfgang and Bader، نويسنده , , Michael، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    11
  • From page
    2582
  • To page
    2592
  • Abstract
    In consideration of its relatively constant urinary excretion rate, creatinine in urine is a useful biochemical parameter to correct the urinary excretion rate of endogenous and exogenous biomolecules. Assays based on the reaction of creatinine and picric acid first reported by Jaffé in 1886 still belong to the most frequently used laboratory approaches for creatinine measurement in urine. Further analytical methods for creatinine include HPLC–UV, GC–MS, and LC–MS and LC–MS/MS approaches. In the present article we report on the development, validation and biomedical application of a new GC–MS method for the reliable quantitative determination of creatinine in human urine, plasma and serum. This method is based on the derivatization of creatinine (d0-Crea) and the internal standard [methyl-trideutero]creatinine (d3-Crea) with pentafluorobenzyl (PFB) bromide in the biological sample directly or after dilution with phosphate buffered saline, extraction of the reaction products with toluene and quantification in 1-μl aliquots of the toluene extract by selected-ion monitoring of m/z 112 for d0-Crea-PFB and m/z 115 for d3-Crea-PFB in the electron-capture negative-ion chemical ionization mode. The limit of detection of the method is 100 amol of creatinine. In an inter-laboratory study on urine samples from 100 healthy subjects, the GC–MS method was used to test the reliability of currently used Jaffé, enzymatic and HPLC assays in clinical and occupational studies. The results of the inter-laboratory study indicate that all three tested methods allow for satisfactory quantification of creatinine in human urine. The GC–MS method is suitable for use as a reference method for urinary creatinine in humans. In serum, creatine was found to contribute to creatinine up to 20% when measured by the present GC–MS method. The application of the GC–MS method can be extended to other biological samples such as saliva.
  • Keywords
    CREATINE , method comparison , Creatinine , Quantification , quality control , Validation
  • Journal title
    Journal of Chromatography B
  • Serial Year
    2010
  • Journal title
    Journal of Chromatography B
  • Record number