Title of article :
Determination of ciprofloxacin in human plasma using high-performance liquid chromatography coupled with fluorescence detection: Application to a population pharmacokinetics study in children with severe malnutrition
Author/Authors :
Muchohi، نويسنده , , Simon N. and Thuo، نويسنده , , Nahashon and Karisa، نويسنده , , Japhet and Muturi، نويسنده , , Alex and Kokwaro، نويسنده , , Gilbert O. and Maitland، نويسنده , , Kathryn، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
7
From page :
146
To page :
152
Abstract :
Clinical pharmacokinetic studies of ciprofloxacin require accurate and precise measurement of plasma drug concentrations. We describe a rapid, selective and sensitive HPLC method coupled with fluorescence detection for determination of ciprofloxacin in human plasma. Internal standard (IS; sarafloxacin) was added to plasma aliquots (200 μL) prior to protein precipitation with acetonitrile. Ciprofloxacin and IS were eluted on a Synergi Max-RP analytical column (150 mm × 4.6 mm i.d., 5 μm particle size) maintained at 40 °C. The mobile phase comprised a mixture of aqueous orthophosphoric acid (0.025 M)/methanol/acetonitrile (75/13/12%, v/v/v); the pH was adjusted to 3.0 with triethylamine. A fluorescence detector (excitation/emission wavelength of 278/450 nm) was used. Retention times for ciprofloxacin and IS were approximately 3.6 and 7.0 min, respectively. Calibration curves of ciprofloxacin were linear over the concentration range of 0.02–4 μg/mL, with correlation coefficients (r2) ≥ 0.998. Intra- and inter-assay relative standard deviations (SD) were <8.0% and accuracy values ranged from 93% to 105% for quality control samples (0.2, 1.8 and 3.6 μg/mL). The mean (SD) extraction recoveries for ciprofloxacin from spiked plasma at 0.08, 1.8 and 3.6 μg/mL were 72.8 ± 12.5% (n = 5), 83.5 ± 5.2% and 77.7 ± 2.0%, respectively (n = 8 in both cases). The recovery for IS was 94.5 ± 7.9% (n = 15). The limits of detection and quantification were 10 ng/mL and 20 ng/mL, respectively. Ciprofloxacin was stable in plasma for at least one month when stored at −15 °C to −25 °C and −70 °C to −90 °C. This method was successfully applied to measure plasma ciprofloxacin concentrations in a population pharmacokinetics study of ciprofloxacin in malnourished children.
Keywords :
HPLC fluorescence detection , Protein precipitation , PLASMA , Validation , Ciprofloxacin
Journal title :
Journal of Chromatography B
Serial Year :
2011
Journal title :
Journal of Chromatography B
Record number :
1472913