• Title of article

    Assessment of photovoltaic pumping systems in Thailand – one decade experience

  • Author/Authors

    Kaunmuang، نويسنده , , P. and Kirtikara، نويسنده , , K. and Songprakorb، نويسنده , , R. and Thepa، نويسنده , , S. and Suwannakum، نويسنده , , T.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2001
  • Pages
    6
  • From page
    529
  • To page
    534
  • Abstract
    By mid 1999 nearly 1000 rural villages in Thailand have been installed with photovoltaic water pumping units. The cumulative wattage is close to 1 MWp. Over 80% are in the Northeast. We conducted a survey between 1995 and 1998 on 489 units, representing over 80% of the units installed then in that region. Interviews were conducted with 360 water users from 18 villages. The results indicate that 45% of the units have been damaged and broken down. Important sources of damages are motor/pump units (35%) and inverters (19%). Inappropriate siting, lack of adequate preparation of villagers and follow-ups by respective agencies are major factors contributing to the untimely damages and breakdown.
  • Keywords
    Photovoltaic pumping systems , Breakdown , Damage
  • Journal title
    Solar Energy Materials and Solar Cells
  • Serial Year
    2001
  • Journal title
    Solar Energy Materials and Solar Cells
  • Record number