• Title of article

    Applications of upwind and downwind schemes for calculating electrical conditions in a wire–plate electrostatic precipitator

  • Author/Authors

    Lei، نويسنده , , Hong and Wang، نويسنده , , Lian-Ze and Wu، نويسنده , , Zi-Niu، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    11
  • From page
    697
  • To page
    707
  • Abstract
    The traditional finite difference method has been widely used to calculate two-dimensional electrical conditions in the wire–plate electrostatic precipitation and the calculation domain has to be confined in the first quadrant of single discharge electrode on the base of the symmetry assumption. In order to remove the symmetry assumption, an unconditional convergent numerical method, in which the upwind (or downwind) scheme was used for the positive (or negative) corona, is presented to calculate the three-dimensional distributions of the electric potential and the space charge in a wire–plate electrostatic precipitator. And the predicted electric potentials agree well with existing experimental data.
  • Keywords
    Downwind scheme , Electrostatic field , Space charge , Electrostatic precipitator , Upwind scheme , Control-volume method
  • Journal title
    Journal of Computational Physics
  • Serial Year
    2004
  • Journal title
    Journal of Computational Physics
  • Record number

    1477773