Title of article
Applications of upwind and downwind schemes for calculating electrical conditions in a wire–plate electrostatic precipitator
Author/Authors
Lei، نويسنده , , Hong and Wang، نويسنده , , Lian-Ze and Wu، نويسنده , , Zi-Niu، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
11
From page
697
To page
707
Abstract
The traditional finite difference method has been widely used to calculate two-dimensional electrical conditions in the wire–plate electrostatic precipitation and the calculation domain has to be confined in the first quadrant of single discharge electrode on the base of the symmetry assumption. In order to remove the symmetry assumption, an unconditional convergent numerical method, in which the upwind (or downwind) scheme was used for the positive (or negative) corona, is presented to calculate the three-dimensional distributions of the electric potential and the space charge in a wire–plate electrostatic precipitator. And the predicted electric potentials agree well with existing experimental data.
Keywords
Downwind scheme , Electrostatic field , Space charge , Electrostatic precipitator , Upwind scheme , Control-volume method
Journal title
Journal of Computational Physics
Serial Year
2004
Journal title
Journal of Computational Physics
Record number
1477773
Link To Document